T: 01568 760671 F: 01568 760484 info@windandsun.co.uk Humber Marsh, Stoke Prior, Leominster, Herefordshire, HR6 0NR
...grid connect Windy Boy inverters

SMA ‘Windy Boy’ Inverters
Windy Boy 2500 Windy Boy 5000A Windy Boy 6000A
Versions of Sunny Boy inverters designed to be used with wind turbines. "Turbine mode" allows the inverter to follow the wind turbine power curve. Units can be linked in parallel allowing operation with a wide variety of wind turbines and to give maximum efficiency.
More information:
Windy Boy Planning Document - How to choose the right Windy Boy for a Wind Turbine
Windy Boy Technical Data
The inverters can be located as close to the wind turbine as desired (even on the tower, IP65 protection), eliminating long DC wire runs. Connection to the mains is via the house consumer unit.
Inverters automatically shut down in the event of: High/Low grid AC voltage; High/Low grid frequency; Grid failure; or Inverter malfunction.
Operating state monitoring and data acquisition are carried out within the Windy Boy inverter. Wind turbine voltage; mains voltage & frequency; input current & power; operating hours and generated kWh energy are measured. Inverters include displays to show essential information or all values can be accessed centrally via a PC or a Sunny Boy Control unit using a choice of communication methods.
Specifications
- Output Voltage Range: 207 -264Vac
- Output Frequency Range: 47.0 -50.5Hz
- Power consumption in operation: ~ 4W
- Power consumption at night (standby): 0.1W.
- Max. efficiency: >93%
- G83 Certification
| Model Number | Description | Input Voltage VDC | Max AC Power | Data Sheets |
| WB-1100LV | Windy Boy 1100W Inverter | 21-60 | 1100 W | WB-1100LV |
| WB-1100 | Windy Boy 1100W Inverter | 139-400 | 1100 W | WB-1100 to 1700 Data Sheet |
| WB-1700 | Windy Boy 1700W Inverter | 139-400 | 1700 W | |
| WB-2500 | Windy Boy 2500W Inverter | 224-600 | 2500 W | WB-2500 / 2800i / 3000 Data Sheet |
| WB-2800i* | Windy Boy 2800W Inverter | 268-600 | 2800 W | |
| WB-3000 | Windy Boy 3000W Inverter | 268-600 | 3000 W | |
| WB-3300 | Windy Boy 3300W Inverter | 200-500 | 3600 W | WB-3300 / 3800 / 6000 Data Sheet |
| WB-3800 | Windy Boy 3800W Inverter | 200-500 | 3800 W | |
| WB-5000A | Windy Boy 5000W Inverter | 246-600 | 5000 W | |
| WB-6000A | Windy Boy 6000W Inverter | 246-600 | 6000 W |
* This product has now been discontinued but there are special offer prices on the remaining stock.
Windy Boy Protection Box
Allows safe use of
Windy Boy inverters with a wide range of wind turbines. It includes
rectifier and overvoltage protection by limiting excessive
voltage and power from the generator and redirects it to a heater
(included). This reliably protects the Windy Boy inverter from high input voltages ensuring troublefree operation.Data Sheet
Available in three versions: 400, 500 and 600V:
| Model Number | Description | ||
| WBP-BOX-400 | WB Rectifier/over-voltage protection inc. resistor 400VDC | ||
| WBP-BOX-500 | WB Rectifier/over-voltage protection inc. resistor 500VDC | ||
| WBP-BOX-600 | WB Rectifier/over-voltage protection inc. resistor 600VDC | ||
| WBP-CABLE | 3-core cable to connect load resistor to WBP-Box | ||
Copyright of Wind & Sun Ltd - no reproduction without express written permission unless for personal use. Registered in England & Wales, Company No.3403803 VAT Number GB 448 5458 14 Registered Office: Humber Marsh,
Stoke Prior, Leominster, Herefordshire, HR6 0NR