Introduction
When planning for a renewable
energy system it is vital to assess your specific requirements ... i.e. what
appliances - lighting, heating, cooking, refrigeration, pumping etc - you want to power
from the installation.
The power requirement of these
functions must be determined, as well as their frequency of use (and in some circumstances
the likely timing of their use, so that the peak requirement at any one time is known).
Conservation of energy usage
may be
feasible in some situations, through for example changing appliances or adjusting ones
lifestyle.
Wind and Sun will be very happy to
help you with these calculations if you wish. Just
contact us
and we can send you an off grid questionnaire to fill in, as a starting point for estimating your
requirements.
After determining these
requirements, and having decided which sources of renewable energy are most suited to the
location, it is necessary to carefully match the individual parts of the system -
batteries, inverters, generators etc.
This process enables one to make
the most efficient use of the energy available, and to have energy available at the
time(s) it is needed.
System Sizing
The precise balance and
size of the components of a wind/solar system depends upon your location and anticipated
power requirements, both 240V 'mains' and low voltage DC.
A wide range of high efficiency
appliances, batteries, controllers and inverters are available to meet most needs.
The number of consecutive days
without sun or wind, together with patterns of use and peak power demand, determine both
the battery store size and inverter or back-up generator requirement. Seasonal as well as
daily variations are important.
If preferred a flexible approach
can be adopted with components added in order of priority and a system expanded by the
addition of additional battery store or generating capacity as needs change or finance
allows.
A useful tool
for estimating monthly output using sunlight data for anywhere in Europe
and Africa is available
here.
Power Requirements in a
battery based system
Both existing and/or
anticipated power requirements must be ascertained as a first step in sizing a system.
Factors to consider include:
- Variety of loads to be run:
eg. domestic lighting, refrigeration, pumps, etc
- Peak Consumption: total
loads that might be required to be run at any one time
- Average Consumption:
typical loads that need to be run most of the time
- Minimum/Continuous Consumption:
any loads that need to be run all the time
- Voltage and frequency: of
required loads, DC or AC
- Pattern of usage: daily,
weekly, and seasonal
- Degree of automation required:
whether supply needs to have 100% availability
In designing a power supply it is
important to consider the whole home as a system; loads are interrelated, eg. correctly
placed windows can help with heating and lighting; insulation reduces heating requirements
etc.
Conservation
This plays an important role in
keeping the costs of any energy supply down.
The use of energy efficient
appliances and lighting, use of non-electric alternatives wherever possible, and increased
awareness of patterns of use, all contribute towards the success and potential for a
renewable energy system.
Cooking and Heating
Conventional electric
cooking, space heating and water heating use a prohibitive amount of electricity.
Electric cookers use about 1500
watts per burner, so bottled gas and solid fuel stoves are usually used for cooking. A
microwave oven has a large power draw, but since food is cooked much more quickly, the
total power consumption may not be too large.
Good passive solar design and
proper insulation can reduce the need for heat, further space heating can be provided by
propane or solid fuel. This is also used for water heating and can be combined with solar
water heating systems.
In the larger wind turbine systems
excess power will be available at times which can be used in immersion heaters, space
heaters and storage heaters. This tends to coincide with colder windy weather but it's
usefulness depends upon system sizing, so some supplementary heat source will still be
necessary.
Refrigeration
Gas powered fridges are a good
choice in small systems if bottled gas is available. If an electric fridge is to be used
then it should be a high efficiency type. The higher cost of good quality DC refrigeration
is more than made up by savings in other system costs.
up to the top
Lighting
In a small home, vehicle,
caravan or boat, the best choice for lighting is usually to run lighting on low voltage DC
directly from the battery.
Wiring runs can be kept short so
relatively small gauge wire can be used, an inverter is not required so system cost is
lower, and if high efficiency DC fluorescent lights etc are used then high levels of
lighting can be obtained from even small systems.
In very large
installations, or ones with existing wiring, or where combined with a diesel generator,
use of an inverter to supply AC power for conventional lighting may be cost effective.
In this case high efficiency
electronic compact fluorescent lights should be used.
Major Appliances
Suitable large electrical
appliances are usually only available in AC versions, -vacuum cleaners, pumps, power
tools, fans, etc. These require a suitably sized inverter.
Washing machines are
usually the largest electrical load in a typical domestic situation.
These will require a large inverter
unless the motors can be replaced by DC motors and the controls modified. However, since
they are run for fixed periods it is usually better to use a standby generator for such
loads and at the same time use any spare capacity for battery charging.
Small Appliances
Many small appliances such
as toasters, irons and hair dryers consume very large amounts of power but require very
short or infrequent use periods.
This means that if the system
inverter, battery and charging system are large enough they may be useable.
Electronic equipment, eg.
stereos, televisions, videos and computers etc have a low power consumption.
Many of these are available in low
voltage DC as well as conventional AC versions, and usually the DC models use less power
than their AC counterparts.
Pumping
This needs to be considered
carefully. In sunny climates direct solar pumping may be advantageous.
Wind Generator/PV Sizing
This is decided so that the battery
store can be maintained from available local renewable resources of wind/solar/& water
or even via a backup generator.
Wind generator &/or PV
output characteristics, together with averages and patterns of windspeed or sunlight
hours, must be considered in choosing the generating equipment.
Wind and solar resources
are often complimentary (high winds & low sun in winter and vice versa) so combining
both can result in a smaller battery store and a overall cheaper and more efficient
system.
up to the top
Location
The expected output from wind and
PV generators depends very much on location, time of year and weather etc. In designing
the optimum system it is important to have as much information as possible regarding local
climatic conditions.
For example:
- Site description
Including position of proposed wind/solar generators relative to loads, location of any
nearby buildings, trees or hills etc.,soil conditions, access conditions, space for
batteries etc.
- Local wind conditions
average wind speed, prevailing directions, seasonal variations and periods of calm
- Solar conditions
average daily hours of sunshine, summer & winter. whether there is any shading
- Other weather conditions
average rainfall, frequency of fog, snow and lightning etc.; average, maximum &
minimum temperatures.
Choosing the Battery
Voltage
The most commonly used
voltage is 12 Volts, for which a wide range of lights and appliances are available.
If long cable runs are required or
if an inverter of more than 1000 watts is needed then a 24 volt system is advisable. Good
24V lighting and some appliances are available but most appliances will be run at 240 VAC
via the inverter.
Higher voltages (usually multiples
of 12) are used in much larger systems and all loads are then inverter powered.
Sizing the Battery
This depends on the power
requirements and also on the required period of available storage -determined by climate
and seasonal weather patterns; availability of standby power (or not); and not least
budget!
For a small system three days
storage might be sufficient. For a remote telecommunications site maybe several weeks.
The amount of electricity stored in
a battery is measured in amp hours. This storage should be sufficient to last several days
without any recharging -bearing in mind that for long life a battery should only be
discharged to 20% capacity before recharging.
| Battery
amp hour capacity |
= |
load
x No. of days storage required x 1.2 |
Normally three to
four days storage will be sufficient, especially if a back-up supply eg. generator is
available.
Actual sizing is very difficult
since the amount of wind or solar charging energy is highly dependent on the weather,
consequently a system that incorporates both wind and solar inputs will require a
considerably smaller battery than one with a sole power source.
Other factors such as criticality
of the loads (resulting in a larger battery store for fail safe operation) and whether
seasonal patterns of consumption match seasonal patterns of generation (allowing a smaller
battery) are also important.
NB. Larger battery banks should
consist of large 2 volt cells connected in series rather than lots of 12V batteries in
parallel in order to avoid circulating currents within the battery and possible early
battery failure.
up to the top
Sizing The Inverter
In addition to the average
power consumption, peak power consumption needs to be considered in sizing the inverter.
This is estimated by adding the
wattages of the largest number of devices that are likely to be operated at the same time.
The continuous rating of the inverter should be greater than this figure.
Most inverters have an overload
capability, for short periods, of two or more times their rated output, and this is needed
for it to cope with the starting surges involved in electric motors -often three times
their rated power. If several motors can start automatically (eg. fridge and freezer) then
it is possible for them to start simultaneously, so their combined starting surge must be
taken account of. If a motor starts when an inverter is already heavily loaded this can
overload the inverter giving a 'black out', so it is advisable to have any other motors
(eg. well pump) on manual control to reduce peak power consumption.
Most of the time an
inverter will only be lightly loaded so it is important to choose one that is efficient at
low load levels as well as at rated output.
Using a Generator
In order not to oversize the
inverter (and so also save on battery and wind/solar costs) a back up generator can be
incorporated and the use of the heaviest loads (eg. washing machine, well pump etc)
restricted to when the generator is running. A battery charger can then also be run with
any spare generating capacity.
The generator should be
sized to cover the likely peak power consumption of all appliances, and the aim should be
to run it for short periods at full capacity.
Such load management and proper
timing of peak power consumption can lead to considerable cost benefits. If loads are
spread out a smaller inverter can be utilised for vacuum cleaning when it's windy or
pumping when sunny means power generated is being used directly - in times of little wind
and sun, energy should be conserved.
Again, selection of
efficient appliances can improve system efficiency.
up to the top
|