Proven
Wind Turbines
These powerful wind turbines, developed in Scotland, are built to withstand severe weather conditions and are a good size for stand alone domestic use, either for battery charging;
for heating; or grid connection.
Their
downwind design incorporates a unique three bladed self-regulating rotor
coupled to a three phase permanent magnet alternator. This give high output
in strong winds combined with good performance in low winds. Under high
wind loading the turbine blades simply turn and flex with the wind -
limiting output, whilst allowing continuing operation even during the
fiercest storms.
Turbine and controller are protected in the event of accidental load
disconnection.
The low rotor speed ensures extended durability of blades & bearings together with quiet operation. No gearbox.
Heavily built machines ensure long life. All components are hot-dipped galvanised steel, stainless steel or plastic. All bearings are triple sealed.
The
2.5kW & 6kW machines include a rotor safety disc brake operated from
the tower base to allow the wind turbine to be stopped for maintenance.
Three
types of system are possible for different applications using different
voltage versions of the wind turbines.
|
Battery
Charging Systems |
For
properties off the grid or where an independent power supply is
required. |
|
Heating
Systems |
Where
power is required for heating in windy weather. |
|
Grid-Connect
Systems |
Allowing
wind power to be used on normal properties to reduce electricity
consumption. |
Proven Specifications
Proven Brochure
Proven 0.6

12, 24
or 48 V - battery charging
These
battery charging machines, developed from the successful 2.5kW version and using
the same blade technology are ideal for remote power supplies such as
homes or telecommunications etc. The controller prevents battery
overcharging and diverts surplus power into a 600W space heater
(included). Meters are available separately. The ECM-601 version
of the controller includes meters, an IP65 enclosure, adjustable low
voltage relay and system status indicators.
|
PROVEN-0.6/012 |
Proven 600W wind turbine 12W |
12V |
|
PROVEN-0.6/024 |
Proven 600W wind turbine 24W |
24V |
|
PROVEN-0.6/048 |
Proven 600W wind turbine 48W |
48V |
For 150 V - grid connect
Used with
Windy Boy WB-700 inverter.
Rectifier includes meters showing voltage and current.
|
PROVEN-0.6/150 |
Proven 600W grid connect wind
turbine |
150V |
Proven 2.5

-
Rating:
2.5kW in a 12m/s (26mph) wind
-
Voltage:
24, 48 or 120 Volts DC
-
Rotor
Diameter: 3.5m
-
Cut
in Windspeed: 2.5m/s (5.6mph)
2.5kW 6.5m mast Data Sheet
2.5kW 6.5m mast Foundation
Pack
2.5kW 11m mast Data Sheet
2.5kW 11m mast Foundation
Pack
The
24 & 48V machines use a battery for storage and can incorporate an
inverter to supply 230Vac power. The controller monitors battery
voltage and diverts surplus power into heaters.
The
120V machine is used for heating only and the controller here matches the
load (storage or immersion heaters etc.) to the wind conditions.
The
standard 6.5m tower is a tubular tapered self-supporting structure
(needing no guy wires) with hinged base plate for easy erection onto a
reinforced concrete base. An 11m tower is also available.
|
PROVEN-2.5/024 |
Proven 2.5kW wind turbine 24W |
24V |
|
PROVEN-2.5/048 |
Proven 2.5kW wind turbine 48W |
48V |
|
PROVEN-2.5/120 |
Proven 2.5kW wind turbine 120V |
120V |
|
PROVEN-2.5/240 |
Proven 2.5kW wind turbine 240V |
240V |
Proven 6
This
wind turbine is ideal for power supplies to homes, farms or small
businesses etc.
6kW Data Sheet
6kW 9m mast Foundation Pack
6kW 15m mast Foundation Pack
48V - battery charging
The
48V machine uses a storage batterr and can incorporate and inverter to
supply 230 Vac power. The controller monitors battery voltage and diverts surplus power into
heaters.
120V
or 240V - direct heating
These
machines are used for direct heating only and the controller matches the
load (storage or immersion heaters) to the wind conditions.
300V
- grid connect
These
are used with two Windy Boy inverters in connection with a normal mains
supply.
Controller
includes isolation switchgear and is suitable for either internal or
external mounting. Version with volt & ammeters for
performance monitoring also available.
|
PROVEN-6/048 |
Proven 6kW wind turbine 48W |
48V |
|
PROVEN-6/120 |
Proven 65kW wind turbine 120V |
120V |
|
PROVEN-6/240 |
Proven 6kW wind turbine 240V |
240V |
|
PROVEN-6/300 |
Proven 6kW wind turbine 300V |
300V |
Accessories
Diversion Heating Loads
For use with battery charge controllers or in direct heating
applications.
DC & AC elements to suit
different controllers.
Immersion elements have
standard fitting.
Winches
Tirfor winches are available for use when raising or lowering towers
or hired when required.
T508 is needed for
Proven 0.6 on 5.5m tower or Proven 2.5 on 6.5m tower;
T516 for Proven 2.5 on
11m;
T532 for Proven 6 on 9m
& T532/30 for Proven 6 on 15m tower.
Proven
Towers
Different tower heights are available to suit different site conditions. The standard towers are
tubular, tapered self-supporting structures made from heavy duty
galvanised steel. They need no guy wires and take up the minimum
of ground area. Includes hinged base plate and gin pole for easy
erection.
Requires a reinforced base.
1m x 1m x 1m for 5.5 & 6.5m towers;
2.5m x 2.5m x 1m for 9 & 11m towers;
3m x 3m x 1m for 15m tower.
Machined tower top adaptors are available for use with custom towers (un-galvanised
upon request).
up
to the top |